Mysterium VPN
Immersion Cooling BC40 PRO Container Accommodate 384 AntMiner S19 XP or 480 WhatsMiner M60 M50

Immersion Cooling BC40 PRO Container Accommodate 384 AntMiner S19 XP or 480 WhatsMiner M60 M50

$161,600
₿ 2.02923
Bitcoin accepted Ethereum accepted Litecoin accepted Bitcoin Cash accepted
X-ON MINING logo
X-ON MINING
2.9

Description

X-ON Immersion Cooling for Crypto Mining
——Provide from Home Mining to Large-scale Mining Solutions
Immersion Cooling BC40 Pro Container – The Ultimate 2.6MW Mining Solution
Technical Specifications:

Dimensions: Standard 40ft high-cube container (L12.2m × W2.44m × H2.9m)
Power Capacity: Supports up to 2.6MW total power load
Miner Compatibility:

384× Antminer S19 series
480× Whatsminer M30/M50 series
Custom configurations available for other ASIC models



Operational Advantages:
Certifications & Standards:

Electrical: UL/CSA/CE
Container: ISO 1496-1
Safety: IP67 rated components
Environmental: RoHS compliant

ROI Benefits:

Energy Savings:

PUE 1.03 (vs 1.25+ for air cooling)
Estimated $58,000/year savings per MW


Increased Uptime:

99.95% operational reliability
3-5 year extended ASIC lifespan


Space Efficiency:

50% more miners per sqm vs air cooling



Ideal Applications:

Large-scale Bitcoin mining farms
Hosting service providers
Renewable energy mining projects
Urban mining installations (low-noise)
Heat recovery/utilization systems

Service & Support:

24/7 remote monitoring included
5-year tank warranty
Onsite training available
Global spare parts network





Deployment Flexibility:
Modular design scales from 168kW to 2.02MW
Mix-and-match configurations
Plug-and-play installation (72hr deployment)


Maintenance Features:
Single-loop isolation valves
Quick-disconnect piping
Tool-free access panels
Self-diagnostic system





Intelligent Management System:
Cooling Control:
Automated flow regulation
Per-tank temperature monitoring
Overheat protection
Power Monitoring:
Real-time kW/TH tracking
Individual miner power consumption
Voltage/current alerts



Advanced Cooling System:
Dual Cooling Options:
Air-cooled dry cooler (standard)
Water cooling tower (optional for higher efficiency)
Temperature Range:
Operating ambient: -25°C to 55°C
Coolant inlet/outlet: 48°C/56°C
Redundancy Design: 10% extra cooling capacity for extreme conditions





Why Professionals Choose Immersion Cooling BC40 Pro:

Proven Reliability: 200+ units deployed worldwide
Future-Proof: Compatible with next-gen ASICs
Complete Solution: Includes all ancillary systems
ESG Ready: Lower carbon footprint and noise pollution

Available Configurations:

Basic: 168kW starter unit
Standard: 1MW mid-scale
Enterprise: 2.6MW full cluster
Custom: Tailored to your specs

Lead Time: 4-6 weeks for standard units
Immersion Cooling BC40 Pro Container video

Support customization
The BC40 MEGA supports customized external cooling options based on the deployment environment and requirements.
geographic location | Ambient temperature Humidity | source of water | overclocking range | Run the type of mining machine



Solution 1: BC40 +Closed Water Tower
Suitable for areas with abundant water resources.
Solution2:  BC40 +Dry Cooler
Suitable for dry and water shortage areas.







BC40 Pro Immersion Cooling System – Technical Specifications
Core System Parameters



Parameter
BASIC
PRO




Dimensions (L×W×H)
12.2m × 2.44m × 2.9m
Same


Weight
13T (shipping) / 23T (operating)
Same


Miner Capacity
384× S19/M50
Same


Cooling Capacity
1,440kW
1,920kW


Max Power Load
1,693kW
2,822kW


Cooling Options
Dry cooler or water tower
Same














Electrical Performance (- /✓ optional/standard)



–

BASIC


PRO



Input Voltage and Frequency
3-phase 350-480V 50/60Hz
3-phase 350-480V 50/60Hz


Max Power Load (kW)
1693
2822


Output Voltage and Frequency
Single-phase 200-277V 50/60Hz
Single-phase 200-277V 50/60Hz


Safety Certification
CE/UL
CE/UL


Operating Power(kW)
100
134


Power Distribution Cabinets(A)
1200Ax1 *2
1000Ax2 *2


PDU
Smart PDU * 16
Smart PDU * 32


Inlet Cable
The inlet cables can withstand high-voltage of above 600V, with the following requirements per phase:L1 4-wires cable 3/0AWG(85mm x4) x1 *2L2 4-wires cable 3/0AWG(85mm x4) x1 *2L3 4-wires cable 3/0AWG(85mm x4) x1 *2N 4-wires cable 3/0AWG(85mm x4) x1 *2PE 1-wire cable 3/0AWG(85mm) x1 *2
The inlet cables can withstand high-voltage of above 600V, with the following requirements per phase:L1 4-wires cable 3/0AWG(85mm x4) x2 *2L2 4-wires cable 3/0AWG(85mm x4) x2 *2L3 4-wires cable 3/0AWG(85mm x4) x2 *2N 4-wires cable 3/0AWG(85mm x4) x2 *2PE 1-wire cable 3/0AWG(85mm) x2 *2


Smart Meter
–
✓


Integrated Wiring
✓
✓


Network
✓
✓


UPS
–
–


SPD
✓
✓






























Cooling Capacity



–

BASIC


PRO



Cooling Capacity(kW)
1440
1920


Cooling Type
Closed water cooling tower
or Dry cooler
Closed water cooling tower
or Dry cooler


Inlet Temperature(℃)
45
45


Outlet Temperature(℃)
60
60


Design Reference Temperature (℃)
35
35









Which Model Is Right For You?
Choose BASIC if:

Running standard S19/M50 at stock speeds
Power costs < $0.08/kWh
Moderate climate conditions

Upgrade to PRO for:

Heavy overclocking (+25% hashrate)
High electricity costs (>$0.10/kWh)
Extreme environments (desert/arctic)

Note: About the transportation of liquid cooling equipment
For most areas, the liquid cooling equipment will be shipped to you via sea freight. Ports and receiving points in different regions will incur different shipping charges. You should contact customer service to confirm the address details and calculate shipping costs before placing an order.
SKU: BC40Pro