Description
Bitmain DCTANK AW1: Industrial-Scale Mining Infrastructure
(376U Rack Space • 120kW Power • 1.11 PUE Efficiency)
The DCTANK AW1 redefines large-scale mining with data-center-grade infrastructure in a shipping container:
✅ 376U Rack Capacity – Holds 100+ Antminer S21 (120 TH/s each)
✅ 120kW IT Load – Powers ≈12 PH/s total hashrate
✅ 1.11 PUE Cooling – 40% more efficient than open-air farms
✅ -40°C to 45°C Operation – Arctic to desert ready
Why Enterprise Miners Choose Bitmain DCTANK AW1?
1. Data Center Performance
1.11 PUE vs. 1.3+ for traditional mining sheds
Pre-installed busbars – No electrician delays
2. Extreme Environment Ready
Arctic Mode: Free cooling below -10°C
Desert Mode: Handles 45°C ambient temps
3. Cluster-Ready Design
Stack 10+ containers for 1 EH+ farms
Hot-swappable components – <1hr maintenance
Bitmain DCTANK AW1 Specifications
Product Overview
Model
DCTANK AW1
Dimensions (l*w*h), mm
6058×2438×2896
Server capacity, U
376
Container certification
CCS
Safety certification
NFPA 79:2024
UL 508A:2018 R7.22
CSA C22.2 No. 301:23
ANSI/ISO 12100:2012
EN ISO 12100:2010
EN 60204-1:2018
Input Voltage and Frequency
400V±5% 50/60Hz
Total IT load, KW
120
Detailed Characteristics
Shipping weight, T
4.6
Main Switch of Power Distribution Cabinets(A)
250×2
Rated current, A
≤405
Number of server cabinets
8
Single cabinet capacity, U
47
Single cabinet power density, KW
15
Inlet cable
The incoming cable requires two three-phase, five-wire cables, each with the following requirements:
L1 single core cable 350kcMil(185mm²)
L2 single core cable 350kcMil(185mm²)
L3 single core cable 350kcMil(185mm²)
N Single-core cable 250kcMil(127mm²)
PE single-core cable 250kcMil(127mm²)
Specification Details For Cooling Tower
Product Overview
Dimensions (l*w*h), mm
6058×2438×2896
PUE(Power usage effectiveness)@ 25℃ ambient temperature
1.11
Rated Cooling Capacity, kW
120
Container certification
CCS
Motor Rated Voltage and Frequency
AV 400V±5%; 50/60Hz
Detailed Characteristics
Shipping Weight, T
5.8
Operating Weight, T
7.8
Supply Air Temperature, ℃
25
Return Air Temperature,˚C
38
Water Consumption @ 25˚C, m3/h
0.2
Noise Level @ 25˚C, 15m, dBA
75
Operating Temperature,˚C
-40~+45
Operation Humidity, RH
5%~95%
(376U Rack Space • 120kW Power • 1.11 PUE Efficiency)
The DCTANK AW1 redefines large-scale mining with data-center-grade infrastructure in a shipping container:
✅ 376U Rack Capacity – Holds 100+ Antminer S21 (120 TH/s each)
✅ 120kW IT Load – Powers ≈12 PH/s total hashrate
✅ 1.11 PUE Cooling – 40% more efficient than open-air farms
✅ -40°C to 45°C Operation – Arctic to desert ready
Why Enterprise Miners Choose Bitmain DCTANK AW1?
1. Data Center Performance
1.11 PUE vs. 1.3+ for traditional mining sheds
Pre-installed busbars – No electrician delays
2. Extreme Environment Ready
Arctic Mode: Free cooling below -10°C
Desert Mode: Handles 45°C ambient temps
3. Cluster-Ready Design
Stack 10+ containers for 1 EH+ farms
Hot-swappable components – <1hr maintenance
Bitmain DCTANK AW1 Specifications
Product Overview
Model
DCTANK AW1
Dimensions (l*w*h), mm
6058×2438×2896
Server capacity, U
376
Container certification
CCS
Safety certification
NFPA 79:2024
UL 508A:2018 R7.22
CSA C22.2 No. 301:23
ANSI/ISO 12100:2012
EN ISO 12100:2010
EN 60204-1:2018
Input Voltage and Frequency
400V±5% 50/60Hz
Total IT load, KW
120
Detailed Characteristics
Shipping weight, T
4.6
Main Switch of Power Distribution Cabinets(A)
250×2
Rated current, A
≤405
Number of server cabinets
8
Single cabinet capacity, U
47
Single cabinet power density, KW
15
Inlet cable
The incoming cable requires two three-phase, five-wire cables, each with the following requirements:
L1 single core cable 350kcMil(185mm²)
L2 single core cable 350kcMil(185mm²)
L3 single core cable 350kcMil(185mm²)
N Single-core cable 250kcMil(127mm²)
PE single-core cable 250kcMil(127mm²)
Specification Details For Cooling Tower
Product Overview
Dimensions (l*w*h), mm
6058×2438×2896
PUE(Power usage effectiveness)@ 25℃ ambient temperature
1.11
Rated Cooling Capacity, kW
120
Container certification
CCS
Motor Rated Voltage and Frequency
AV 400V±5%; 50/60Hz
Detailed Characteristics
Shipping Weight, T
5.8
Operating Weight, T
7.8
Supply Air Temperature, ℃
25
Return Air Temperature,˚C
38
Water Consumption @ 25˚C, m3/h
0.2
Noise Level @ 25˚C, 15m, dBA
75
Operating Temperature,˚C
-40~+45
Operation Humidity, RH
5%~95%
SKU: DCTANK AW1