Brewery Chiller - BrewChill Pro 13000 - 13000 BTUs
$2,830.15
₿ 0.03681
Key specifications
- MODEL
- BC-13000-2
- CAPACITY
- 13000 BTU/H
- RUNNING
- With 1 pump - 12.7 AMPWith 2 pimps - 15.5 AMP
- VOLTAGE
- 208/230 V
- FREQUENCY
- 60 HZ
- PUMP
- 80 GPH
Specifications
- MODEL
- BC-13000-2
- CAPACITY
- 13000 BTU/H
- RUNNING
- With 1 pump - 12.7 AMPWith 2 pimps - 15.5 AMP
- VOLTAGE
- 208/230 V
- FREQUENCY
- 60 HZ
- PUMP
- 80 GPH
- REFRIGERANT
- R290
- Easy installation and setup
- Plug-and-play with external digital thermostats for precise, effortless temperature control.
Description
Specifications
Specifications
Manual
Thermostat settings
At 13,000 BTU, the BrewChill Pro 13000-2 is a glycol chiller built for a tank room that's running at full capacity, not a startup setup anymore. Two independently controlled pumps draw from an 18 gallon reservoir and can reach glycol lines up to 750 feet away, which covers most production floor layouts without needing a second chiller nearby. The dual zone design means one line can hold a brite tank cold while another handles active fermentation, without either one pulling temperature away from the other.Production breweries reach for this size when they're running several tanks at once around the clock, and the same output supports wineries and cideries cooling a full cellar during a harvest crush.
Key Features:
13,000 BTU/h cooling capacity: 1+1 HP compressors on R290 refrigerant deliver strong wort chilling and fermentation temperature control for Canadian brewery equipment running continuously.
Dual-zone operation: Two built-in 80 gal/hr vane pumps, each on a 1/3 HP motor, provide independent temperature control across multiple fermentation tanks.
Energy-efficient performance: R290 natural refrigerant keeps this glycol chiller running efficiently with stable, reliable cooling and low environmental impact.
Compact, quiet, and durable build: Suited to microbreweries, brewpubs, and home brewers who want professional-grade glycol chillers with minimal noise and upkeep.
Extended line reach: Glycol lines run up to 750 ft, giving flexibility to place tanks and chiller across your brewing facility.
Built for professional brewing: Engineered for long-term reliability under demanding, continuous brewing and fermentation conditions.
Parts included:
1 x Glycol chiller with an 80 gal/hr recirculation pump, 1/3 hp motor
1 x External Digital Thermostat
4 x Solenoid Valves
BrewChill Pro 13000 - Canada
MAXIMUM DISTANCE
Up to 750 ft
GLYCOL TANK CAPACITY
18 gallons
COMPRESSOR POWER
1+1HP
PLUG TYPE (NEMA #)
6-20P
PUMP TYPE
Vane with 1/3hp motor
NUMBER OF PRE-INSTALLED PUMPS
2
NUMBER OF ADDITIONAL PUMPS
0
REFRIGERANT CHARGE, G (OZ)
150 (5.29)
WEIGHT GROSS/NET
238 / 231 lb
POWER CORD LENGTH
6 ft
INLET/OUTLET BARB, IN
red tube 3/4” NPT / blue tube 3/4” NPT
OPERATING AMBIENT TEMPERATURE
60-90 F
CLEARANCE AT LEAST
12" around the entire unit
GLYCOL MIXTURE, VOL%
40 % glycol and 60% water
Note: Installation of this item must be handled by a qualified installer in order to qualify for product return and/or warranty coverage. Qualified Installer - Defined as a licensed professional who charges a fee for his services, and possesses a business license, contractor's license, and/or resale permit. Common examples of a "qualified installer" include Electrician; General Contractor; Heating and Air Conditioning Specialist.
Run your production floor layout through our brewery chiller sizing calculator to confirm 13,000 BTU and 750 foot glycol lines cover your space. If your cooling equipment sits in a room that gets washed down regularly, the BrewChill Pro 13000SS-2 offers the same output in a stainless housing built for that. Still weighing the two cabinet options? Contact us and we will help you choose.
Specifications
Manual
Thermostat settings
At 13,000 BTU, the BrewChill Pro 13000-2 is a glycol chiller built for a tank room that's running at full capacity, not a startup setup anymore. Two independently controlled pumps draw from an 18 gallon reservoir and can reach glycol lines up to 750 feet away, which covers most production floor layouts without needing a second chiller nearby. The dual zone design means one line can hold a brite tank cold while another handles active fermentation, without either one pulling temperature away from the other.Production breweries reach for this size when they're running several tanks at once around the clock, and the same output supports wineries and cideries cooling a full cellar during a harvest crush.
Key Features:
13,000 BTU/h cooling capacity: 1+1 HP compressors on R290 refrigerant deliver strong wort chilling and fermentation temperature control for Canadian brewery equipment running continuously.
Dual-zone operation: Two built-in 80 gal/hr vane pumps, each on a 1/3 HP motor, provide independent temperature control across multiple fermentation tanks.
Energy-efficient performance: R290 natural refrigerant keeps this glycol chiller running efficiently with stable, reliable cooling and low environmental impact.
Compact, quiet, and durable build: Suited to microbreweries, brewpubs, and home brewers who want professional-grade glycol chillers with minimal noise and upkeep.
Extended line reach: Glycol lines run up to 750 ft, giving flexibility to place tanks and chiller across your brewing facility.
Built for professional brewing: Engineered for long-term reliability under demanding, continuous brewing and fermentation conditions.
Parts included:
1 x Glycol chiller with an 80 gal/hr recirculation pump, 1/3 hp motor
1 x External Digital Thermostat
4 x Solenoid Valves
BrewChill Pro 13000 - Canada
MAXIMUM DISTANCE
Up to 750 ft
GLYCOL TANK CAPACITY
18 gallons
COMPRESSOR POWER
1+1HP
PLUG TYPE (NEMA #)
6-20P
PUMP TYPE
Vane with 1/3hp motor
NUMBER OF PRE-INSTALLED PUMPS
2
NUMBER OF ADDITIONAL PUMPS
0
REFRIGERANT CHARGE, G (OZ)
150 (5.29)
WEIGHT GROSS/NET
238 / 231 lb
POWER CORD LENGTH
6 ft
INLET/OUTLET BARB, IN
red tube 3/4” NPT / blue tube 3/4” NPT
OPERATING AMBIENT TEMPERATURE
60-90 F
CLEARANCE AT LEAST
12" around the entire unit
GLYCOL MIXTURE, VOL%
40 % glycol and 60% water
Note: Installation of this item must be handled by a qualified installer in order to qualify for product return and/or warranty coverage. Qualified Installer - Defined as a licensed professional who charges a fee for his services, and possesses a business license, contractor's license, and/or resale permit. Common examples of a "qualified installer" include Electrician; General Contractor; Heating and Air Conditioning Specialist.
Run your production floor layout through our brewery chiller sizing calculator to confirm 13,000 BTU and 750 foot glycol lines cover your space. If your cooling equipment sits in a room that gets washed down regularly, the BrewChill Pro 13000SS-2 offers the same output in a stainless housing built for that. Still weighing the two cabinet options? Contact us and we will help you choose.
SKU: BC-13000-2-ASM
More from Toronto Brewing
All products$2,830.15
₿ 0.03681